| VS Series Model 01 Storage Systems |
The new VS Series Storage Systems that can be used in liquid nitrogen, oxygen or argon service is now offered by Chart in a wide range of sizes for applications requiring operating pressures at 175 and 250 psig (12 and 17 bar) as standard. Other pressures available upon request. Chart offers this equipment designed in accordance with ASME code.
Our composite insulation system gives you the competitive edge with high thermal performance, extended hold times, low life-cycle costs and light weight to reduce operational and installation costs. Chart leads the industry with an innovative modular piping system designed for performance, durability and low maintenance. |
| Benefits |
- Piping modules designed for ease-of-access to all operational control valves with stainless steel interconnecting piping to minimize the number of connections, reducing maintenace and cost of ownership.
- Component selection to improve operational performance Combination Pressure Building/Economizer Regulator for easy pressure adjustment and extended Bonnet Bronze Control Valves for ease of operation.
- High performance safety system with dual relief valves and rupture disks supplied as a standard.
- Backed by an industry-leading warranty.
|
|
| * 400, 500 psig tanks are available upon request
(NER) = Nominal Evaporation Rate |
** Weights are for ASME designs
|
| Nomenclature |
| C-1 |
Connection, Aux Liquid |
| C-2 |
Connection, Aux Vapor |
| C-3 |
Connection, Secondary Aux Liq |
| C-4 |
Connection, Secondary Aux Vapor |
| CV-1 |
Check Valve, Fill |
| CV-3 |
Check Valve, Economizer |
| FC-1 |
Connection Fill |
| HCV-1 |
Valve, Bottom Fill |
| HCV-2 |
Valve, Top Fill |
| HCV-3 |
Valve, PB Inlet |
| HCV-4 |
Valve, Full Trycock |
| HCV-5 |
Valve, Vacuum Gauge Tube |
| HCV-7 |
Valve, Fill Line Drain |
| HCV-8 |
Valve, LI-1 Vapor Phase |
| HCV-9 |
Valve, LI-1 Equalization |
| HCV-10 |
Valve, LI-1 Liquid Phase |
| HCV-11 |
Valve, PB Outlet |
| HCV-12 |
Valve, Vapor Vent |
| HCV-13 |
Valve, Product Supply |
| HCV-15 |
Valve, Safety Relief Selector |
| HCV-17 |
Valve, Economizer |
|
| LI-1 |
Level Indicator, Inner Vessel |
| PBC-1 |
Pressure Buiding Coil, Inr. Ves. |
| PCV-1 |
Pressure Control Valve |
| PI-1 |
Pressure Indicator, Inner Vessel |
| PSE-1A |
Pressure Safety Element, Inr. Ves. |
| PSE-1B |
Pressure Safety Element, Inr. Ves |
| PSV-1A |
Pressure Safety Valve, Inr. Ves. |
| PSV-1B |
Pressure Safety Valve, Inr. Ves. |
| S-1 |
Strainer, Pressure Buiding |
| TSV-2 |
Thermal Safety Valve, Fill |
| TSV-3 |
Thermal Safety Valve, Economizer |
| TSV-4 |
Thermal Safety Valve, PB Circuit |
| VP-1 |
Vacuum Port |
| VR-1 |
Vacuum Readout, Outer Vessel |
| Note : Optional valves (not shown) |
| HCV-18 |
Valve, Liquid Withdrawal (From C-1) |
| HCV-19 |
Valve, Vapor Return (From C-2) |
| HCV-21 |
Valve, Sec Aux Liquid (From C-3) |
| HCV-22 |
Valve, Sec Aux Vapor (From C-4) |
|
| * Dashed lines represent
optional components |
| C-8 |
Connection, Customer Houseline |
| CV-2 |
Check Valve, Houseline |
| HCV-16A |
Valve, Relief Line Purge |
| HCV-16B |
Valve, Relief Line Purge |
| HCV-20 |
Valve, Economizer Vent |
| HCV-30 |
Valve. Inlet Houseline |
| HCV-31 |
Valve, Bypass Houseline |
| HCV-32 |
Valve, Outlet Houseline |
| PCV-3 |
Pressure Control Valve,
Econo Vent |
| PCV-5 |
Pressure Control Valve, Houseline |
| PI-2 |
Pressure Indicator, Houseline |
| S-2 |
Strainer, Fill |
| TSV-8 |
Thermal Safety Valve, Houseline |
| VAP |
Vaporizer, Product Withdrawal |
|
|
 |
|
|
|